General provisions of the glass-aluminum curtain wall fireproof, as follows:

1) between Windows, window sill wall fillings nonflammable material should be used, when the outer walls with fire resistance not less than 100h fire body, filling material can be difficult burning material within its walls.

2) no walls between Windows and window sills of the glass curtain wall, should be installed at each floor edge fire resistance not less than 100h, not less than 0.8M in height walls do not burn solid skirt.

3) at each floor, wall and glass curtain wall cracks, should use incombustible material tightly filled.